HiDefServers has partnered with ACS, Inc. and the Orange County Data Center to offer customers the most state of the art facility in Southern California. This facility was designed with safety, security, fire resistance, and weather protection in mind.

Boasting over 65,000 square feet of raised, ventilated flooring and other amenities, our fully redundant facility was designed to be safe and secure. Running out of drive space? Just call or email our technicians and we can add extra hard drive space almost instantly. Like our downtown Los Angeles datacenter, our Santa Ana datacenter is manned 24 hours a day/7 days a week.

Utility Power

Each of our LAX facilities comes equipped with different power densities per cabinet. Our One Wilshire facility has power density up to 25 KWs per cabinet, the 600 West 7th cabinets has power density from 6 kWs per and higher and the newest LAX facility at 800 South Hope boasts AC 120V/240V for each cabinet, with 480V 3 phase available.

Back-Up Power & Generator

The facilities are all equipped with N+1 and redundant AC/DC UPS power, ensuring servers keep running and stay online in the event that power is lost. Our One Wilshire facility also has 2N DC power available. The generators in both One Wilshire and 600 West 7th facilities are setup with 2N and N emergency generator configuration, keeping servers online in the case of a major outage. The generators at the 800 South Hope facility have a 6-2000 KW diesel generator in the event that power is lost and the UPS runs out of juice. This ensures power is constantly flowing to the cabinets.

Security & Protection Features

Our customer's servers remain secure with 24x7 staffing and site access, mantraps, CCTV surveillance, and biometric access control. Like all of our datacenters, the 800 South Hope facility has a 24/7 CCTV system with card access control to ensure only certified staff is able to enter.

Datacenter Specs

  • 65,000 sq. ft of raised flooring with over 14,000 sq. feet of colocation space
  • 24/7/365 secured facility
  • 24/7/365 VPLS Technical Assistance Center access
  • Dual Liebert 750kVA UPS battery backup N+1 design with over 480
  • 22,000 volt power feeds from redundant Edison circuits
  • Dual 1 Megawatt CAT generators
  • 12,500 gallons of diesel fuel on site
  • Halon 1301 Fire Suppression system
  • Designed for flexible architecture to withstand an earthquake of magnitude 8.0
  • "Erector Set" type of design allows building to flow with earth's movements
  • Plumbing is spring mounted to ensures that all parts move accordingly